In summer a geothermal system rejects heat into the ground instead of extracting it. The failure modes are the mirror image of the winter ones.
Know where to stop
Everything below is a check any homeowner can safely make. Anything involving opening a sealed refrigerant circuit, working inside an energized panel, or dismantling a gas train needs a licensed technician — not because we want the call, but because that is where people get hurt.
If you smell gas, leave the building and call the gas utility from outside.
Free things to try before you call
A good share of the calls we go out on turn out to be one of these. Try them first, and you may save yourself a service charge.
- 01
Check the thermostat is on COOL with the fan on AUTO
- 02
Replace the air filter and open all registers
- 03
Check breakers for the unit and the loop circulator pumps
- 04
Note any fault code shown on the unit’s control board
- 05
Check loop pressure if your system has an accessible gauge
- 06
Listen for circulator pumps running on a call for cooling
- 07
Check the condensate drain has not backed up and tripped a float switch
What it probably is
These are the most likely causes. Open one to see what it looks like and what fixing it involves.
1Low loop flow
Again, this is the most common cause. Without enough flow the system cannot reject heat into the ground and will lock out on high pressure rather than damage the compressor.
2A failed circulator pump
No flow means nowhere for the heat to go. The unit protects itself by shutting down.
3A stuck reversing valve
It leaves the system in heating mode, which is unmistakable in July.
4Condensate drain blockage
Geothermal units produce condensate in cooling exactly like any other system, and a blocked drain will trip the float switch and stop the unit.
5Refrigerant charge issues
This is less common on a sealed geothermal system than on an air-source unit, but it can happen, and it shows as gradually weakening capacity.
Common follow-ups
Why does my geothermal system lock out in summer?
Usually a high-pressure trip caused by poor loop flow — the system cannot reject heat, pressure rises, and the safety stops it. That protection is what saves the compressor.
Is geothermal cooling as effective as a regular AC?
Generally more so, and considerably cheaper to run, because ground temperature is far more stable than the 95°F air an ordinary condenser is fighting on an August afternoon.
Do I still need annual maintenance on geothermal?
Yes. Loop pressure, pump operation, controls, coil and condensate all want checking, and catching a slow loop leak early is much cheaper than discovering it in January.
Prefer to call?
(423) 357-1922- Office hours
- Monday to Friday, 8–5
- Outside those hours
- Emergency service is available — call the same number.
- Where we go
- Church Hill, Kingsport, Mount Carmel, Surgoinsville, Rogersville, Johnson City, Bristol, Greeneville, Morristown and across into Southwest Virginia. Full service area.
- Where we are
- 119 E Main St, Church Hill, TN 37642
Still not working after these checks?
That is what we are here for, and emergency service is available.
(423) 357-1922